| File Reference : | GG-7-22 Legionella Safety |
| Date File Updated | 07-10-26 |
| Category | General Guidance | Tags: ISO 45001, 8.1, 6.1 |
Included in the alphaZ subscription
Every alphaZ document and toolkit, with updates as they are released. Everything you download is yours to keep.
You are logged in as an alphaZ subscriber
This document's file is ready to download from the Download Files tab below.
This guidance covers the legionella risk review, temperature checks at outlets and tanks, flushing and what goes in the legionella management plan.
This guidance document is supplied in fully editable MS Word format and can be easily customised and edited. The document uses pre-defined style formatting throughout, with all text in Calibri font for improved readability.
The following document labelling is included in the footer:
- Guidance number and title
- Information-classification
- Version
- Page number / total pages
Further guidance on legionella and water systems:
Download this guidance document with your company name and logo already added!
Document Preparation is included with the alphaZ subscription.
This file is included in the alphaZ subscription.
If you'd like hands-on help completing your legionella risk review and management plan, our remote support services provide direct expert input from our team, by the day, by project, or on an ongoing basis.
Legionella Safety Guidance
A general guidance document on legionella safety, for the people responsible for the water systems in the premises. It explains how legionella and Legionnaires' disease arise, how the water system is reviewed for risk factors, the outlet and tank checks, flushing and other controls, and what goes in the legionella management plan.
Topics Covered
- Legionella and Legionnaires' disease - how the disease is caught, and the warm, stagnant or sprayed water conditions that raise the risk
- Managing legionella risk - reviewing the water system to identify risk factors and recording them on a risk review or risk assessment
- Water system and dead legs - a plan of the whole water system, and removing dead legs and redundant pipework where water stagnates
- Checking outlets - cold and hot water temperature checks at each outlet, with the points that trigger action, and water quality checks
- Water tank checks - periodic inspection of tanks for damage, contamination and temperature, with draining, cleaning and disinfecting where needed
- Other risk factors - infrequently used outlets, higher-risk systems such as showers, unoccupied periods, activities that create spray and changes to the system
- The legionella management plan - recording the controls, monitoring, checks and responsibilities, a schematic of the system, and planned risk reviews by a competent person
Who Is It For?
Managers and responsible persons who look after the water systems in the premises, and anyone who carries out the checks, flushing or cleaning.
Using the Guidance
Give it to the responsible person for your water systems and anyone carrying out checks or flushing, and keep it as a reference alongside your legionella records. Record who has received it, for example on the training matrix.
Temperature Checks at Outlets and Tanks
The guidance gives clear points that trigger action. Cold water above 20°C after running for up to two minutes, or hot water that does not reach at least 50°C within one minute, needs correcting. Tanks are checked for hot water below 60°C, cold water above 20°C, damage, loose lids, sludge and missed draining or cleaning.
Adapting the Guidance
Edit the guidance to match your own arrangements - the responsible person for your water systems, the outlets and tanks in your premises, any higher-risk systems such as showers or eye wash stations, and your flushing routine.
Related Documents
Other documents that work alongside this guidance:
- RA-HS62 Legionella Risk Assessment
- F-HS36 Legionella Risk Review
- F-HS37 Legionella Management Plan
- GG-1-06 Management of Equipment and Premises
Flushing Outlets and Empty Premises
Infrequently used outlets are run weekly for at least two minutes, and after the premises have been unoccupied for more than two weeks all outlets are flushed safely, avoiding spray. For planned closures such as holidays, weekly flushing of all outlets reduces the risk.
Would you rather we prepared it for you?
A day of remote support can take the risk assessments you already have, move them into one consistent format with the same scoring throughout, and build your hazard register from them, so the hazards this guidance covers are backed by a current assessment.
These files are for alphaZ subscribers. Log in to the subscriber library once and each file below downloads straight away. Not a subscriber yet? See the alphaZ subscription.
Each file downloads straight away. You can also browse the subscriber library.
- GG-7-22 Legionella Safety Word, 47 KB